非能动安注箱的设计与分析Design and analysis of passive safety injection tank
郑华,臧希年
摘要(Abstract):
介绍了非能动安注箱的设计与实验,并用CATHENA程序分析其特性:注入流量的峰值,高注入流量的持续时间,最低注入流量等。计算结果表明非能动安注箱设计满足主要的性能要求,CATHENA程序计算结果与实验数据基本一致,可用于概念设计与事故分析。
关键词(KeyWords): 非能动安注箱;CATHENA;流控设备;热工水力数值模拟
基金项目(Foundation):
作者(Author): 郑华,臧希年
参考文献(References):
- [1] Makihara Y, et al. Development of the hybrid safety system for next generation PWR[J]. Progress in Nuclear Energy, 1995, 29(supplement):353-360.
- [2] Chung H J, et al. Performance evaluation of passive safety injection flow controllers for the APR1400 reac-tor[C]. Proceedings of ICONE10: Tenth International Conference on Nuclear Engineering, Arlington, Virginia, USA, April 14-18, 2002.
- [3] In-Cheol CHU, et al. Performance evaluation of a passive safety injection flow controller for APR1400[C]. Proceedings of 13th PBNC: 13th Pacific Basin Nuclear Conference, Shenzhen, China, 2002.
- [4] Hanna BN, CATHENA: A thermalhydraulic code for CANDU analysis[J], Nuclear Engineering and Design, 1998, 180:113-131.
- [5] Hanna BN, et al. CATHENA MOD-3. 5c/Rev 0 Input Reference[M].